GRADE-SPECIFIC FUNCTIONS AND FEATURES
PRO- | B | S | H | ECO | |
---|---|---|---|---|---|
1 | All models are 6-digit display, complies with 0.5 grade JIS B 7738. | O | O | O | O |
2 | Set Length and find Load (Normal Testing). | O | O | O | O |
3 | Set Load and find Length (Special Testing). | X | O | O | Manual |
4 | Set Deflection and find Load (Special Testing). | O | O | O | Manual |
5 | Set Load and find Deflection (Special Testing). | X | O | O | Manual |
6 | N, mN, can be switched units (gf, kgf, (lb)). | O | O | O | O |
7 | Length resolution is 0.01mm (○) and 0.001mm (1 micron) (◎). | O | O | ◎ | O |
8 | 3-Step Testing through setting on Length. | O | O | O | Manual |
9 | 3-Step Testing through setting on Load. | X | O | O | Manual |
10 | Multiple Step Testing for Load or Length with START, STEP & END input. | X | X | O | X |
11 | Spring Rate, Free Length, Initial Tension for Tension Spring & Solid Height for Compression Spring. | O | O | O | O |
12 | Peak Load for Disc (Flat) Spring | O | O | O | O |
13 | Inching control of 1mm, 0.1mm, 0.01mm, (0.001mm for (◎). | O | O | ◎ | Manual |
14 | Store 50 setting conditions and can be recall for testing. | O | O | O | O |
15 | Setting of tolerance and view with bar chart on screen to determine OK or NG. | O | O | O | O |
16 | By ± key or the {eb9cfd4e3b516869cb839b8b2c338ebd16b99827caa87fe8648376116c5dd92c} key, there is an automatic calculation function of standards and tolerance. | O | O | O | O |
17 | OK printing (Print only when Pass) and NG printing (Print only when Fail) and AUTO to print all results. | O | O | O | O |
18 | When NG , there will be an * asterisk mark besides the results during printing. | O | O | O | O |
19 | Dual units printing is possible (Example : N and kgf). | O | O | O | O |
20 | Output Port to print through connecting to Mitutoyo Digimatic Caliper, Micrometers, etc on the dimension. | O | O | O | × |
21 | Automatic Load Zero reset function can be set in the System. | O | O | O | O |
22 | Test Speed of 1 ~ 600 / min. | O | O | O | Manual |
23 | Interval Time 1 ~250Sec. | O | O | O | Manual |
24 | Maintenance-free AC servo motor to the driving unit. | O | O | O | Manual |
25 | High Performance Load Cell with 300{eb9cfd4e3b516869cb839b8b2c338ebd16b99827caa87fe8648376116c5dd92c} overload protection. | O | O | O | O |
26 | Auto Origin function to compensate Deflection of Load Cell and also memorize into the tester. | O | O | O | O |
27 | Auto High / Low Range Switch over changing the resolution | O | O | O | O |
28 | Emergency Stop Button | O | O | O | O |
29 | RS-232C Interface as standard accessories. | O | O | O | X |
30 | Optional to add Bar Code Scanner to retrieve setting conditions | O | O | O | X |
31 | Optional Software to run under Microsoft Windows Environment. | O | O | O | X |